Batatia, Kovács, Simm, Ortner, Csányi, Cambridge, ENS Paris-Saclay and UBC (NeurIPS 2022) — ARXIV-2206.07697
Key takeaways
- Many-body messages (§4): a two-body equivariant feature A_i is pooled over neighbors, then a product basis B_i is formed from ν-fold tensor products of A_i with itself, which gives (ν + 1)-body messages without summing over pairs or triplets explicitly. The expensive tensor product runs on edges once; the higher-order products run on nodes. Readouts are linear except the last, to keep the body order
- Two layers (Figure 1, 3BPA): two-body models (NequIP, BOTNet) need up to five layers to converge; MACE with ν = 3 converges at two. The 3BPA molecule is about 9 Å across and the cutoff is 5 Å, so two layers already see the whole molecule
- Learning curves (Figure 2, aspirin, rMD17, force MAE): invariant MACE with ν = 1, 2, 3 has slopes −0.33, −0.51, −0.64. At ν = 3, raising L from 0 to 1 to 2 leaves the slope at −0.64, −0.63, −0.64 and shifts the curve. At ν = 1, L = 1 and 2 steepen it to −0.44 and −0.45
- rMD17 (Table 1, 950 training configurations): aspirin forces 6.6 meV/Å against NequIP 8.2 and Allegro 7.3. Allegro is lower on six of the ten molecules’ forces. With 50 training configurations MACE beats NequIP on all ten molecules’ forces (aspirin 43.9 against 52.0)
- 3BPA extrapolation (Table 2, RMSE, trained at 300 K): at 1200 K, forces 62.0 meV/Å for MACE L = 2, 76.2 for NequIP in its own code, 86.4 for NequIP in the MACE code, 83.0 for Allegro. Invariant MACE (L = 0) has latency 10.5 ms against 103.5 ms for NequIP in the MACE code, with force errors at or above the equivariant models’ (300 K: 14.6 against 10.8–13.0)
- Acetylacetone (Table 3): MACE has lower force error at 300 K and 600 K; NequIP has the lower energy error at 300 K (0.81 against 0.9 meV)
Standing in the anthology
Filed from the graph-coverage pass (gap list from the record’s own
review, 2026-10-22). It is compared_against NequIP (LIT-832), which it
benchmarks on rMD17, 3BPA and acetylacetone, re-implements in its own code
for timing, and re-reads. NequIP attributed its steeper learning curve to
equivariance; MACE’s Figure 2 replicates the aspirin experiment and finds an
invariant model of higher body order steepens the curve as much, while
equivariance at fixed high body order only shifts it. THEORY-131 is that
finding stated as an explanation.
The speed claim is measured in one codebase. Every timing in Table 2 is
from the authors’ mace code, with NequIP and BOTNet re-implemented there.
The paper says itself that “accurate speed comparisons between codes are
hard to obtain”. The 30-minute training figure on 3BPA is against BOTNet
taking more than a day, on A100s.
“State of the art” on rMD17 is shared. MACE is best on aspirin, paracetamol and toluene forces; Allegro is lower on most of the others, and most entries are within a few tenths of a meV/Å.
Read — NOTE-393.