Source

Batatia et al. (2022), LIT-828. Read as NOTE-393. Batzner et al. (2021), LIT-832. Read as NOTE-389.

The account

NequIP (LIT-832) observed that its equivariant networks (l = 1, 2, 3) learn faster with data than the same network restricted to l = 0, on bulk water from 10 to 1,000 structures and on aspirin from 150 to 950, and that the l = 0 network keeps its shallow slope even when matched to l = 1 in weights or in features. It concluded that “it is indeed the equivariant nature of NequIP” that changes the learning behaviour.

The l = 0 network there is a two-body model: each message depends on one neighbor’s state and one distance. Turning on l = 1 does two things at once. It makes the features equivariant, and it lets angular information between pairs of neighbors survive into the next layer, which raises the effective body order. NequIP’s control matched size, not body order.

MACE (LIT-828, Figure 2) separates the two on the same aspirin task, rMD17 force MAE against training-set size, two-layer models:

  • Body order, invariant features only. Correlation order ν = 1, 2, 3 (two-, three- and four-body messages) gives slopes −0.33, −0.51, −0.64
  • Equivariance at high body order. At ν = 3, symmetry order L = 0, 1, 2 gives −0.64, −0.63, −0.64. The curves shift down; the slope does not move
  • Equivariance at low body order. At ν = 1, L = 0, 1, 2 gives −0.33, −0.44, −0.45. Here equivariance does steepen the curve, which is the NequIP shape, since L = 1 messages carry angular information a two-body invariant message cannot

So equivariant features steepen the curve when they are the only route to higher body order, and stop doing so once body order is supplied another way. An invariant four-body model reaches the slope of the equivariant ones.

What it explains

  • Why NequIP’s l = 0 → 1 step changed the slope and l = 1 → 3 only shifted it: the first step adds angular correlation, the later ones refine it
  • Why NequIP’s weight- and feature-matched l = 0 controls did not recover the slope: neither raises body order
  • Partly, why invariant MACE (L = 0), a four-body model, sits among the two-body equivariant models on 3BPA at 1200 K (forces 81.6 against 76.2–86.4 meV/Å, energy 37.1 against 38.5–42.6 meV) at a tenth of their latency (Table 2). At 300 K it is behind them (forces 14.6 against 10.8–13.0), which this account does not explain

Why Proposed

One molecule, one group, a figure. The slopes come from aspirin alone, over roughly one decade of training size, with no error bars on the fitted exponents. Without intervals, the −0.63 against −0.64 that carries the central claim cannot be told apart from a real but small effect.

The reverse control is partial. Body order was raised with equivariance held at L = 0, and equivariance raised at fixed ν. Nobody has raised body order in a model of the NequIP family and checked that the slope moves the same way there.

What it does not say

It does not say equivariance is useless. At every body order, adding L shifts the curve down, which at fixed data is lower error, and MACE’s best models use L = 2. The claim is about the exponent, not the error.

It does not say anything at large data. Both papers stop below about 1,000 configurations. Erwin (LIT-763) found equivariant graph models, NequIP among them, leading at small training sets and overtaken as data grew, on a different task; this account neither predicts nor contradicts that.